Hammond Transformers Model 193P (193 Series)
D.C. Filter Choke - 5 H, 500 ma, 26 Ohms, 800 Volts D.C.
This enclosed common mode D.C. filter choke is perfect for high voltage power supply filtering. Its case matches power transformers & tube audio output transformers. The units are vacuum impregnated with polyurethane varnish for quiet and long-life operation.
Proper Henry testing requires an LCR meter in junction with a 25A power supply that does allow for DC bias as well a higher applied AC drive voltage to meet the test specifications.
Features:
- Enclosed, 4-hole mount chokes
- Tolerance of 15% on both inductance & resistance.
- Inductances measured at rated D.C. current.
- Minimum 8" long leads.
- Units will exhibit less inductance at slightly higher currents or more at lower currents.
- Perfect for high voltage power supply filtering, case matches power transformers & tube audio output transformers.
- Units are vacuum impregnated with polyurethane varnish for quiet and long-life operation.
- Operating temperature range is -40C to 65C
- Insulation class 105C
- Proper Henry testing requires an LCR meter in junction with a 25A power supply that does allow for DC bias as well a higher applied AC drive voltage to meet the test specifications.
Specifications:
- Inductance: 5 H (+/- 15%)
- DC current: 500ma
- Resistance: 26 Ohms (+/- 15%)
- Maximum Operating Volt (D.C.): 800V
- Minimum Operating Temperature: -40 C
- Maximum Operating Temperature: +85 C
- Termination Style: Wire Leads
- Type: Enclosed
- Mounting Style: Chassis Mount
- Number of Channels: 1
- Weight: 10.75 lbs
- Length: 3.75”
- Width: 4.5”
- Height: 4.56”
See download for detailed product dimensions
Manufacturer's Warranty