Hammond Transformers Model 269GX (200 Series)
Classic Plate and Filament Power Transformer - 48 VA, 450V C.T. @ 75 mA, 6.3V @ 2.5 A Filament #1
This high voltage primary transformer can be run full wave bridge or full wave C.T. These units are enclosed 4-hole chassis mount and have Class A insultation (105 C).
Features:
- Primary 115 VAC, 60 Hz.
 - For "universal" primaries and/or 50/60 Hz. operation and other output voltage combinations please see Hammond’s 300 Series.
 - Enclosed, 4-hole, chassis mount.
 - Minimum 6" long leads.
 - Units can be run full wave bridge or full wave C.T.
 - Class A insulation (105 degrees C).
 - Hi-Pot test of 2,000V RMS.
 - Conservative designs - CSA certified (209651).
 
Choice #1 (115 VAC Input):
For those customers who need the 115V input - nothing has changed - simply use the White & Gray wires and tape the Black wire (see schematic on Series Spec Sheet in download section).
Choice #2 (125 VAC Input):
For those customers who are seeing too high a secondary voltage due to higher primary line voltages (roughly 125V input) - use the White & Black wire and tape the gray wire (see schematic on Series Spec Sheet in download section).
NOTE: Most of the "Z" mounts do not apply to choices #1 and #2 above. See their respective drawings, on the Series Spec Sheet in the download section, for available primary voltages.
CAUTION
NEVER connect power to BOTH the GRAY & BLACK wire - instantaneous destruction of the transformer will result!
Specifications:
- Primary Voltage Rating: 115 VAC
 - Secondary Voltage Rating: 450 VAC CT
 - Operating Frequency: 60 Hz
 - Operating Temperature Range: 0 C to + 105 C
 - Power Rating: 48 VA
 - Secondary Current Rating: 75 mA
 - Filament #1 (VAC): 6.3V @ 2.5 A
 - Primary Winding: Single
 - Secondary Winding: Dual
 - Shielding: Enclosed
 - Termination Style: Wire leads
 - Mounting Style: Chassis Mount 4-hole
 - Width: 2.19”
 - Depth: 2.63”
 - Height: 2.63”
 
Manufacturer's Warranty